1 edition of IEEE recommended practice for grounding of industrial and commercial power systems. found in the catalog.

IEEE recommended practice for grounding of industrial and commercial power systems.

IEEE recommended practice for grounding of industrial and commercial power systems.

Sponsor: Industrial and Commercial Power Systems Committee of the IEEE Industry Applications Society.

by

  • 162 Want to read
  • 18 Currently reading

Published by Institute of Electrical and Electronics Engineers in [New York] .
Written in English

    Subjects:
  • Electric currents -- Grounding

  • Edition Notes

    ContributionsIEEE Industry Applications Society. Industrial and Commercial Power Systems Committee, Institute of Electrical and Electronics Engineers
    Classifications
    LC ClassificationsTK3227 I2 1972
    The Physical Object
    Pagination95p.
    Number of Pages95
    ID Numbers
    Open LibraryOL22339870M

    IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (The Green Book) Power stations and substations “For satisfactory lightning protection, substation grounding network resistance must not exceed 5 ohm; for large stations lower values are more desirable.” Recommended acceptable values.   P is the Recommended Practice for Evaluating the Electrical Service Requirements of Industrial and Commercial Power Systems. P/D3 was balloted. The task group has completed work on the majority of the ballot comments (see attached). One of the first standards to address bonding and grounding was IEEE , Recommended Practice for Grounding of Industrial and Commercial Power Systems (the Green Book) when Chapter 5 was added in the edition – Electronic Equipment Grounding.


Share this book
You might also like
Jessicas mother

Jessicas mother

Toward independent living

Toward independent living

Personnel management

Personnel management

Nomination of Cowan and Sullivan.

Nomination of Cowan and Sullivan.

In review; Canadian books for young people.

In review; Canadian books for young people.

Loyalty & humanity; or, a variety of scenes which a clergyman of the established church, and his family, evidenced and came through, in a disturbed part of Ireland, during the late troubles; with his observations on them.

Loyalty & humanity; or, a variety of scenes which a clergyman of the established church, and his family, evidenced and came through, in a disturbed part of Ireland, during the late troubles; with his observations on them.

Targeting the powerful

Targeting the powerful

Kleinere Schriften (Gesammelte Werke)

Kleinere Schriften (Gesammelte Werke)

Venture capital in Malaysia

Venture capital in Malaysia

Harmonizing Bach Chorales

Harmonizing Bach Chorales

Prayer

Prayer

Improved administration needed in New Jersey for the federal program of aid to educationally deprived children.

Improved administration needed in New Jersey for the federal program of aid to educationally deprived children.

Canada as a home.

Canada as a home.

More, Please, An Autobiography.

More, Please, An Autobiography.

Westminster School

Westminster School

Real Estate

Real Estate

Physical culture and sport in the GDR

Physical culture and sport in the GDR

The Nautical Almanac for the year 1990.

The Nautical Almanac for the year 1990.

IEEE recommended practice for grounding of industrial and commercial power systems. Download PDF EPUB FB2

Obtaining a low-resistance connection to earth, use of ground rods, connections to water pipes, etc., are discussed. A separate chapter on electronic equipment is included.

- IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems. IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (IEEE Green Book) by Institute of Electrical and Electronics Engineers (Author)5/5(1).

IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems Abstract: Superseded by IEEE Std (Green Book). This IEEE Standars product is part of the Color Books family. The problems of system grounding, that is, connection to ground of neutral, of the corner of the delta, or of the midtap of one phase, are.

IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (IEEE Green Book) Abstract: The problems of system grounding, that is, connection to ground of neutral, of the corner of the delta, or of the midtap of one phase, are covered.

IEEE StdIEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (The IEEE Green Book) [Institute of Electrical & Electronics Engineers] on *FREE* shipping on qualifying offers.

IEEE StdIEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (The IEEE Green Book)5/5(2). IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems Abstract: The problems of system grounding, that is, connection to ground of neutral, of the corner of the delta, or of the midtap of one phase, are covered.

Discussed in this recommended practice is the system grounding of industrial and commercial power systems. The recommended practices in this document are intended to provide explanations of how electrical systems operate. It can also be an aid to all engineers responsible for the electrical design of industrial and commercial power systems.

Obtaining a low-resistance connection to the earth, use of ground rods, connections to water pipes, etc.

is discussed. A separate chapter on sensitive electronic equipment is included. - IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (IEEE Green Book).

IEEE Recommended Practice for Equipment Grounding and Bonding in Industrial and Commercial PowerSystems Abstract: The grounding and bonding of equipment in industrial and commercial power systems is covered in this recommended practice.

The interconnection and grounding of the non-electrical metallic elements of a system is covered first. - IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems The ANSI/IEEE Stdthe IEEE Buff Book, deals with the proper selection, application, and coordination of the components which constitute system protection for industrial plants and commercial buildings.

IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems Abstract: The ANSI/IEEE Stdthe IEEE Buff Book, deals with the proper selection, application, and coordination of the components which constitute system protection for industrial plants and commercial buildings.

IEEE Std. IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (Color Book Series) on *FREE* shipping on qualifying offers. IEEE Std.IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (Color Book Series)Price: $ IEEE Green Book ™.

This recommended practice has served electrical engineers seeking electrical system grounding information since the first edition in It reflects the experience and sound judgment of a working group made up of engineers active in the design and operation of electrical systems for industrial IEEE recommended practice for grounding of industrial and commercial power systems.

book commercial power systems. known as the ÒGray BookÓ is published by the Institute of Electrical and Electronics Engineers (IEEE) to provide a recommended practice for the electrical design of commercial buildings. It has been prepared on a voluntary basis by engineers and designers functioning as the Gray Book Working Group within the IEEE Power Systems Engineering Size: KB.

The problems of system grounding, that is, connection to ground of neutral, of the corner of the delta, or of the midtap of one phase, are covered. The advantages and disadvantages of grounded versus ungrounded systems are discussed. Information is. IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems Chapter 1 System Grounding Introduction Grounding of an electrical system is a decision that must be faced sometime by most engineers charged with planning or modifying electrical distribution.

IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems Sponsor Power Systems Engineering Committee of the IEEE Industry Applications. Recommended Practice for Grounding of Industrial and Commercial Power Systems This book is a revision of IEEE Stdthe IEEE Green Book ™.

This recommended practice has served electrical engineers seeking electrical system grounding information since the first edition IEEE IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (Green Book) The problems of system grounding, that is, connection to ground of neutral, of the corner of the delta, or of the midtap of one phase, are covered.

The advantages and disadvantages of grounded vs. ungrounded systems are discussed. Recommended Practice for the Application of Medium Voltage Fuses in Industrial and Commercial Power Systems Progress STD Recommended Practice for the Application of Low -Voltage Circuit Breakers in Industrial and Commercial Power Systems Published P Recommended Practice for the Application of Ground Fault Protection (First Draft File Size: 1MB.

IEEE Recommended Practice for the Design of Reliable Industrial and Commercial Power Systems (The IEEE Color Book Series: Gold Book) [Not Available] on *FREE* shipping on qualifying offers. IEEE Recommended Practice for the Design of Reliable Industrial and Commercial Power Systems (The IEEE Color Book Series: Gold Book)/5(2).

This Recommended Practice addresses the uses, power sources, design, and maintenance of emergency and standby power systems. Chapter 3 is a general discussion of needs for and the configuration of emergency and standby systems.

Chapter 9 lists the power needs for specific industries. Chapters 4 and 5 deal with the selection of power sources. In the IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (Green Book) states: “System grounding is the intentional connection to ground of a phase or neutral conductor for the purpose of: a) Controlling the voltage with respect to earth, or ground, within predictable limits” My questions were.

content; An overview of IEEE The Emerald Book. This standard seeks to bring order to the apparent chaos of power quality assurance by describing recommended practices for powering and grounding sensitive electronic electronic loads proliferate and take on more important roles in companies and our lives, so do power quality concerns.

IEEE Std IEEE green book, grounding I.E.E.E. recommended practice for grounding of industrial and commercial power systems: Responsibility: sponsor, Power System Engineering Committee of the IEEE Industry Applications Society ; approved JIEEE Standards Board ; approved December 9,American National Standards Institute.

IEEE recommended practice for equipment grounding and bonding in industrial and commercial power systems / sponsor, Technical Books Coordinating Committee of the IEEE Industry Applications Society. Also Titled. Recommended practice for equipment grounding and bonding in industrial and commercial power systems IEEE Std Other Authors.

For the Electrical Engineer in an industrial or a Commercial application environment, the IEEE Standards Collection™ for Industrial & Commercial Power Systems, formerly the Color Books, are presently the most comprehensive collection of recommended practices available.

Additional Physical Format: Online version: IEEE recommended practice for grounding of industrial and commercial power systems.

[New York]: Institute of Electrical and Electronics Engineers: Distributed in cooperation with Wiley-Interscience, © Ma San Francisco IEEE/IAS Chapter Seminar Basic objectives of an equipment grounding system: 1. To reduce electric shock hazard to personnel.

To provide adequate current carrying capability, both in magnitude and duration, to accept the ground-fault current permitted by the overcurrent protection system withoutFile Size: 2MB. RE: IEEE StdIEEE Recommended Practice for Determining the Reliability of 7×24 Continuous Power Systems in Industrial and Commercial Facilities.

WG Dear IAS Members, This is a reminder to register for out next free webinar, “Overview of IEEE ” presented by Neal Dowling and Robert Arno on April 5, at AM EST. Get this from a library.

IEEE recommended practice for grounding of industrial and commercial power systems. [IEEE Industrial Application Committee. Industrial and Commercial Power Systems Committee.; Institute of Electrical and Electronics Engineers.;]. IEEE Std (Green Book) Recommended Practice for Grounding of Industrial and Commercial Power Systems The reasons for limiting the current by resistance grounding may be one or more of the following.

1) To reduce burning and melting effects in faulted electric equipment, such as switchgear, transformers, cables, and rotating Size: 3MB. IEEE StdIEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (The IEEE Green Book) by Institute of Electrical & Electronics Engineers | Jun 1, out of 5 stars 2.

IEEE Std. – IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (commonly called the Green Book) IEEE Std. 80 - IEEE, “Guide for Safety in AC Substation Grounding” Electrical Instruments in Hazardous Locations by Ernest C.

Magison has an excellent chapter human electrical safety. Soares' "Book on. IEEE Std ™ IEEE Recommended Practice for Calculating Short-Circuit Currents in Industrial and Commercial Power Systems Sponsor Power Systems Engineering Committee of the IEEE Industry Applications Society Approved 9 May IEEE-SA Standards Board Approved 2 October American National Standards Institute.

Synchronous Generator Systems, IEEE Standard C, 5. IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (The Green Book), IEEE Standard6.

IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (The Buff Book), IEEE Standard7. Task Force established in IEEE NesCom approved the PAR for the Rail Potential Guide and Working Group in Par P, EXPIRATION DATE OF December - IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (Green Book.

NTRODUCTION TO ARTICLE —GROUNDING AND BONDING: Recommended Practice for Grounding of Industrial and Commercial Power Systems (Green Book) [], the resistance of the soil outward from a ground rod is equal to the sum of the series resis-tances of the earth shells.

The shell nearest the rod has. Get this from a library. IEEE recommended practice for grounding of industrial and commercial power systems.

[Institute of Electrical and Electronics Engineers.; IEEE Industrial Application Committee. Power System Technologies Committee.]. IEEE StandardRecommended Practice for Grounding of Industrial and Commercial Power Systems, aka the Green Book. Presents a thorough investigation of the problems of grounding and the methods for solving these problems.

There is a separate chapter for grounding File Size: 17KB. Industry standards such as “IEEE standard ” (Emerald Book) “Recommended Practice for Powering and Grounding Sensitive Electronic Equipment” and “IEEE standard ” (Green Book) “Recommended Practice for Grounding of Industrial and Commercial Power Systems” and others such as NFPA and military standards provide.His industrial experience ranges from conceptual design, control and operation of power systems to computer software design and development.

His areas of expertise include cable systems, grounding, short-circuit, transient stability, and protective device coordination. He is a Life Fellow of IEEE and Chairman of the IEEE Working Group.[2] IEEE Std“ IEEE Recommended Practice for Grounding of Industrial and Commercial Power systems (Green book)”, [3] Alstom Grid, “ Network Protection and Automation Guide”, May [4] Preve, C., “Protection of Electrical Networks”,ISTE Ltd, London [5] Fielding, G., “Protection of MV Industrial Networks”,